Features and Benefits
- Detection kit for Toxoplasma gondii
- Available in TaqMan format for analysis
Toxoplasma gondii is a single-celled organism which causes Toxoplasmosis, the most common parasitic infection worldwide affecting animals as well as humans. Cats are the only animal in which sexual reproduction of the organism occurs, and for this reason cats are the only domestic animal which has the potential to shed T. gondii eggs. When disease does occur, it may develop following primary infection due to an inadequate immune response to stop the invasive tachyzoites or as a result of a reactivated infection due to a compromised immune system. The most common symptoms of the disease are anorexia, weight loss, lethargy, dyspnea, ocular symptoms and pyrexia. As toxoplasmosis can be transmitted to humans it represents a serious health risk for people living in close contact with infected animals. Infection is especially dangerous for people with suppressed immune systems and cancer patients as well as pregnant women.
Click to expand options
Toxoplasma gondii TaqMan PCR Kit,
100 reactions
- Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
- Specific Primer and Probe mix for the pathogen/virus/viroid of interest
- Primer and Probe mix
- Positive and negative control to confirm the integrity of the kit reagents
Toxoplasma gondii TaqMan PCR Probe/Primer Set and Controls,
100 reactions
- Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
- Nuclease-free water
- Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix
Details
Supporting Data
Previous
TaqMan PCR Kit - Figure 1. Example of TaqMan PCR Positive result. Both PCR signals above the baseline from FAM and HEX channel indicate the successful PCR.
TaqMan PCR Kit - Figure 2. Example of TaqMan PCR Negative result. No target DNA was detected in FAM channel but amplification signal from HEX indicates the successful PCR.
TaqMan PCR Kit - Figure 3. Example of TaqMan PCR inhibition result. No signal from both FAM and HEX channel was detected. It is suggested to repeat the sample preparation using recommended kit for DNA purification.
Click for expanded view
Storage Conditions
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Component | TaqMan Probe Cat. TM44750 (100 preps) |
TaqMan Probe Cat. TM44710 (100 preps) |
---|---|---|
MDx TaqMan 2X PCR Master Mix | 2 x 700 µL | - |
Toxoplasma gondii Primer Probe Mix | 280 µL | 280 µL |
Toxoplasma gondii Positive Control | 150 µL | 150 µL |
Nuclease-Free Water (Negative Control) | 1.25 mL | 1.25 mL |
Product Insert | 1 | 1 |